生物技术通报 ›› 2017, Vol. 33 ›› Issue (12): 81-86.doi: 10.13560/j.cnki.biotech.bull.1985.2017-0291

• 技术与方法 • 上一篇    下一篇

一种快速检测含tst基因的金黄色葡萄球菌的纳米生物传感器

李明阳1, 贺气志2, 马春霞1, 俞建昆1   

  1. 1. 中国医学科学院 北京协和医学院 医学生物学研究所 中心实验室,昆明 650118;
    2. 长沙医学院 基础医学院 应用生物学教研室,长沙 410219
  • 收稿日期:2017-04-12 出版日期:2017-12-25 发布日期:2017-12-21
  • 作者简介:李明阳,男,硕士研究生,研究方向:RNA甲基化;E-mail:403124921@qq.com;贺气志,女,硕士研究生,研究方向:生物传感器技术及致病菌的耐药干预;E-mail:314190831@qq.com,贺气志为共同第一作者
  • 基金资助:
    高等学校博士学科点专项科研基金资助项目(20111106120056)

A Nano Biosensor for Rapid Detecting Staphylococcus aureus Containing tst Gene

LI Ming-yang1, HE Qi-zhi2, MA Chun-xia1, YU Jian-kun1   

  1. 1. Central Laboratory,Institute of Medical Biology,Chinese Academy of Medical Science & Peking Union Medical College,Kunming 650118;
    2. Department of Applied Biology,School of Basic Medical Science,Changsha Medical University,Changsha 410219
  • Received:2017-04-12 Published:2017-12-25 Online:2017-12-21

摘要: 基于荧光能量共振转移(Fluorescence energy resonance transfer,FRET)原理利用单壁碳纳米管(Single-walled carbon nanotubes,SWCNTs)构建一种操作简单、成本低、灵敏度高和选择性强的纳米生物传感器快速检测含有tst基因金黄色葡萄球菌。将tst基因互补序列设计为探针,利用单壁碳纳米管联合羧基荧光素(FAM)标记的DNA分子探针(FAM-P)构建出FAM-P/SWCNTs复合检测体系。考察该体系对靶标序列和靶标菌的灵敏度和特异性。结果表明,该生物传感器对靶标序列的检测下限低至10 nmol/L,并在10-100 nmol/L 范围内具有较好的线性关系(R2= 0.994),对靶标菌的检测下限低至102,且在102-107 CFU/mL范围内均呈现良好的线性关系(R2= 0.999)。此外,在错配实验和对非靶标菌检测时,该传感器呈现了较高的特异性。本研究构建的FAM-P/SWCNTs体系能快速检测含tst基因金黄色葡萄球菌,并具有操作简单、灵敏度高、特异性强等优点,为食品检测、临床诊断等领域开辟了新途径。

关键词: 单壁碳纳米管, 荧光标记的核酸探针, tst 基因, 金黄色葡萄球菌

Abstract: This work is to construct a nano biosensor of simple operation,low cost,high sensitivity and specificity to rapid detect Staphylococcus aureus containing tst gene with single-walled carbon nanotubes(SWCNTs)based on the principle of fluorescence energy resonance transfer(FRET). SWCNTs combined with carboxyfluorescein(FAM)-labeled DNA molecule probes(FAM-P)were used to construct FAM-P/SWCNTs composite detection system,and the probe was complementary molecular sequence of tst gene. The sensitivity and specificity of the system to the target sequence and the target strain were investigated. As results,the lower detection limit of target sequence was 10 nmol/L and presented a fine linear relationship(R2 was 0.994)in the range of 10-100 nmol/L. The detection limit of the target strain was as low as 102 and in the range of 102-107 CFU/mL(R2 was 0.999). In addition,the sensor exhibited a high specificity in mismatch experiments and for non-target bacteria detection. In conclusion,the composite detection system by FAM-P/SWCNTs has the advantages of rapid detection,simple operation,high sensitivity and strong specificity,which opens up a new approach for food detection and clinical diagnosis.

Key words: single-walled carbon nanotubes, carboxyfluorescein-labeled nucleic acid probes, tst gene, Staphylococcus aureus